Targeted Server Family (Machine Type): ThinkServer DN8848 V2 (7D6A,7D6H,7D8V,7D8U) |
Targeted Operating System: Microsoft Windows Server 2019 | Known Server Limitations/Issues and Solutions |
Microsoft Windows_Server Bundle Build Date: 2022_11_29 |
How to use Lenovo Microsoft Windows Device Driver Bundles |
Portable Bundle Download |
This download is a single self-contained compressed (.7z file) copy of the entire bundle thats supports every device listed below. Downloading this bundle is the fastest and easiest way to update your server or build a deployment image. Bundle contains only drivers, bundle Readme.txt files contain links to required firmware and recommended utility updates. Firmware/utility download information is also contained in the tables below. | |
DN8848V2_7D6A_7D6H_7D8V_7D8U-Windows_Server_2019-2022_11_29.7z (File size: 7.5MB Download) | Lenovo GnuPG Authenticity Signature |
How to verify the Intergity and Authenticity of Lenovo Driver Bundles and public key download, click here |
Supported Devices, Drivers, Firmware and Utilities |
ThinkServer 128GB TruDDR4 3200 MHz (1.2V) Intel Optane DC Persistent Memory |
Part Number: 4X77A64902 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Lenovo Persistent Memory FW update (For Windows) | pm200-02.02.00.1553-2 | ||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
InBox Driver provided by Microsoft Windows Server install supported | N/A | N/A |
ThinkSystem 430-16i SAS/SATA 12Gb HBA
|
Part Number: 7Y37A01089 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0201 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem 430-x SAS/SATA 12Gb HBA update BIOS and Firmware (For Windows) | mpt3.5.430-18.03.00.00-2 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
itsas35.sys | 2.61.29.02 | lnvgy_itsas35_2.61.29.02.zip | Signature | ||
lsinodrv.sys | 2.61.29.02 | lnvgy_lsinodrv_2.61.29.02.zip | Signature | ||
Utility | Utility Description - Download Page Link (lenovo.com) | Version | |||
StorCLI command line tool (For Windows) | mpt3.storcli-007.1907.0000.0000-0 |
ThinkSystem RAID 530-8i PCIe 12Gb Adapter
|
Part Number: 4Y37A09771 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0500 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware (For Windows) | mr3.5.530-51.17.0-4094-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
megasas35.sys | 7.719.06.00 | lnvgy_megasas35_7.719.06.00.zip | Signature | ||
nodev.sys | 7.719.06.00 | lnvgy_nodev_7.719.06.00.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
LSI Storage Authority Software (For Windows) | mr3.lsa-007.019.006.000-0 | ||||
StorCLI command line tool (For Windows) | mr3.storcli-007.1907.0000.0000-0 |
ThinkSystem RAID 530-16i PCIe 12Gb Adapter
|
Part Number: 4Y37A09727 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0503 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem RAID 530-x Adapters update BIOS and Firmware (For Windows) | mr3.5.530-51.17.0-4094-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
megasas35.sys | 7.719.06.00 | lnvgy_megasas35_7.719.06.00.zip | Signature | ||
nodev.sys | 7.719.06.00 | lnvgy_nodev_7.719.06.00.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
LSI Storage Authority Software (For Windows) | mr3.lsa-007.019.006.000-0 | ||||
StorCLI command line tool (For Windows) | mr3.storcli-007.1907.0000.0000-0 |
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
|
Part Number: 7Y37A01084 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0601 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware (For Windows) | mr3.5.930-51.17.0-4094-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
megasas35.sys | 7.719.06.00 | lnvgy_megasas35_7.719.06.00.zip | Signature | ||
nodev.sys | 7.719.06.00 | lnvgy_nodev_7.719.06.00.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
LSI Storage Authority Software (For Windows) | mr3.lsa-007.019.006.000-0 | ||||
StorCLI command line tool (For Windows) | mr3.storcli-007.1907.0000.0000-0 |
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
|
Part Number: 7Y37A01085 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0602 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem RAID 930-x xGB Flash PCIe 12Gb Adapters2Gb Adapters update BIOS and Firmware (For Windows) | mr3.5.930-51.17.0-4094-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
megasas35.sys | 7.719.06.00 | lnvgy_megasas35_7.719.06.00.zip | Signature | ||
nodev.sys | 7.719.06.00 | lnvgy_nodev_7.719.06.00.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
LSI Storage Authority Software (For Windows) | mr3.lsa-007.019.006.000-0 | ||||
StorCLI command line tool (For Windows) | mr3.storcli-007.1907.0000.0000-0 |
ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
|
Part Number: 4Y37A09728 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x060A | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem RAID 940-x Flash PCIe 12Gb Adapters update BIOS and Firmware (For Windows) | mr3.5.940-52.17.0-4093-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
megasas35.sys | 7.719.06.00 | lnvgy_megasas35_7.719.06.00.zip | Signature | ||
nodev.sys | 7.719.06.00 | lnvgy_nodev_7.719.06.00.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
LSI Storage Authority Software (For Windows) | mr3.lsa-007.019.006.000-0 | ||||
StorCLI command line tool (For Windows) | mr3.storcli-007.1907.0000.0000-0 |
ThinkSystem M.2 SATA 2-Bay RAID Enablement Kit |
Part Number: 4Y37A09739 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
M.2 with Mirroring Enablement Kit Firmware Update (For Windows) | sata-2.3.20.1011-0 | ||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
mv91cons.sys | 1.2.0.1050 | lnvgy_mv91cons_1.2.0.1050.zip | Signature | ||
Utility | Utility Description - Download Page Link (lenovo.com) | Version | |||
mvcli command line tool (For Windows) | sata.mvcli-2.3.10.1095-0 |
ThinkSystem M.2 NVMe 2-Bay RAID Enablement Kit |
Part Number: 4Y37A09750 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Nvme 7mm/M.2 with Mirroring Enablement Kit Firmware Update (For Windows) | nvme-1.0.20.1051-0 | ||||
Utility | Utility Description - Download Page Link (lenovo.com) | Version | |||
mnvcli command line tool (For Windows) | nvme.mnvcli-1.0.20.1048-0 | ||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
InBox Driver provided by Microsoft Windows Server install supported | N/A | N/A |
Intel VROC Premium key |
Part Number: 4Y37A09794 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
iaVROC.sys | 7.7.0.1260 | intc_iaVROC_7.7.0.1260.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
Intel VROC GUI Utility for Windows (For Windows) | vroc.7.5-7.7.0.1273-0 | ||||
Intel VROC CLI Utility for Windows (For Windows) | vroc.cli.7.5-7.7.0.1273-0 |
Intel VROC standard key |
Part Number: 4Y37A09795 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
iaVROC.sys | 7.7.0.1260 | intc_iaVROC_7.7.0.1260.zip | Signature | ||
Utilities | Utility Description - Download Page Link (lenovo.com) | Version | |||
Intel VROC GUI Utility for Windows (For Windows) | vroc.7.5-7.7.0.1273-0 | ||||
Intel VROC CLI Utility for Windows (For Windows) | vroc.cli.7.5-7.7.0.1273-0 |
ThinkServer I350-T4 PCIe 1GbE 4-Port RJ45 Ethernet Adapter |
Part Number: 4XC7A62588 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
InBox Driver provided by Microsoft Windows Server install supported | N/A | N/A |
ThinkServer Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter |
Part Number: 4XC7A62590 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Driver | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
InBox Driver provided by Microsoft Windows Server install supported | N/A | N/A |
ThinkServer Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet adapter |
Part Number: 4XC7A62591 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
e1d68x64.sys | 12.19.1.37 | intc_e1d68x64_12.19.1.37.zip | Signature | ||
e1r68x64.sys | 12.18.13.0 | intc_e1r68x64_12.18.13.0.zip | Signature | ||
e1s68x64.sys | 12.15.184.4 | intc_e1s68x64_12.15.184.4.zip | Signature | ||
i40ea68.sys | 1.16.62.0 | intc_i40ea68_1.16.62.0.zip | Signature | ||
i40eb68.sys | 1.16.62.0 | intc_i40eb68_1.16.62.0.zip | Signature | ||
ixn68x64.sys | 4.1.239.0 | intc_ixn68x64_4.1.239.0.zip | Signature | ||
ixs68x64.sys | 4.1.246.0 | intc_ixs68x64_4.1.246.0.zip | Signature | ||
ixt68x64.sys | 4.1.228.0 | intc_ixt68x64_4.1.228.0.zip | Signature | ||
sxa68x64.sys | 4.1.243.0 | intc_sxa68x64_4.1.243.0.zip | Signature | ||
sxb68x64.sys | 4.1.239.0 | intc_sxb68x64_4.1.239.0.zip | Signature | ||
v1q68x64.sys | 1.4.7.3 | intc_v1q68x64_1.4.7.3.zip | Signature | ||
vxn68x64.sys | 2.1.241.0 | intc_vxn68x64_2.1.241.0.zip | Signature | ||
vxs68x64.sys | 2.1.230.0 | intc_vxs68x64_2.1.230.0.zip | Signature |
ThinkServer Intel X550-T2 Dual Port 10GBase-T Adapter
|
Part Number: 4XC7A62592 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
e1d68x64.sys | 12.19.1.37 | intc_e1d68x64_12.19.1.37.zip | Signature | ||
e1r68x64.sys | 12.18.13.0 | intc_e1r68x64_12.18.13.0.zip | Signature | ||
e1s68x64.sys | 12.15.184.4 | intc_e1s68x64_12.15.184.4.zip | Signature | ||
i40ea68.sys | 1.16.62.0 | intc_i40ea68_1.16.62.0.zip | Signature | ||
i40eb68.sys | 1.16.62.0 | intc_i40eb68_1.16.62.0.zip | Signature | ||
ixn68x64.sys | 4.1.239.0 | intc_ixn68x64_4.1.239.0.zip | Signature | ||
ixs68x64.sys | 4.1.246.0 | intc_ixs68x64_4.1.246.0.zip | Signature | ||
ixt68x64.sys | 4.1.228.0 | intc_ixt68x64_4.1.228.0.zip | Signature | ||
sxa68x64.sys | 4.1.243.0 | intc_sxa68x64_4.1.243.0.zip | Signature | ||
sxb68x64.sys | 4.1.239.0 | intc_sxb68x64_4.1.239.0.zip | Signature | ||
v1q68x64.sys | 1.4.7.3 | intc_v1q68x64_1.4.7.3.zip | Signature | ||
vxn68x64.sys | 2.1.241.0 | intc_vxn68x64_2.1.241.0.zip | Signature | ||
vxs68x64.sys | 2.1.230.0 | intc_vxs68x64_2.1.230.0.zip | Signature |
ThinkServer Intel X710-T2L 10GBASE-T 2-port OCP Ethernet Adapter |
Part Number: 4XC7A62593 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
e1d68x64.sys | 12.19.1.37 | intc_e1d68x64_12.19.1.37.zip | Signature | ||
e1r68x64.sys | 12.18.13.0 | intc_e1r68x64_12.18.13.0.zip | Signature | ||
e1s68x64.sys | 12.15.184.4 | intc_e1s68x64_12.15.184.4.zip | Signature | ||
i40ea68.sys | 1.16.62.0 | intc_i40ea68_1.16.62.0.zip | Signature | ||
i40eb68.sys | 1.16.62.0 | intc_i40eb68_1.16.62.0.zip | Signature | ||
ixn68x64.sys | 4.1.239.0 | intc_ixn68x64_4.1.239.0.zip | Signature | ||
ixs68x64.sys | 4.1.246.0 | intc_ixs68x64_4.1.246.0.zip | Signature | ||
ixt68x64.sys | 4.1.228.0 | intc_ixt68x64_4.1.228.0.zip | Signature | ||
sxa68x64.sys | 4.1.243.0 | intc_sxa68x64_4.1.243.0.zip | Signature | ||
sxb68x64.sys | 4.1.239.0 | intc_sxb68x64_4.1.239.0.zip | Signature | ||
v1q68x64.sys | 1.4.7.3 | intc_v1q68x64_1.4.7.3.zip | Signature | ||
vxn68x64.sys | 2.1.241.0 | intc_vxn68x64_2.1.241.0.zip | Signature | ||
vxs68x64.sys | 2.1.230.0 | intc_vxs68x64_2.1.230.0.zip | Signature |
ThinkServer Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter |
Part Number: 4XC7A62579 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
e1d68x64.sys | 12.19.1.37 | intc_e1d68x64_12.19.1.37.zip | Signature | ||
e1r68x64.sys | 12.18.13.0 | intc_e1r68x64_12.18.13.0.zip | Signature | ||
e1s68x64.sys | 12.15.184.4 | intc_e1s68x64_12.15.184.4.zip | Signature | ||
i40ea68.sys | 1.16.62.0 | intc_i40ea68_1.16.62.0.zip | Signature | ||
i40eb68.sys | 1.16.62.0 | intc_i40eb68_1.16.62.0.zip | Signature | ||
ixn68x64.sys | 4.1.239.0 | intc_ixn68x64_4.1.239.0.zip | Signature | ||
ixs68x64.sys | 4.1.246.0 | intc_ixs68x64_4.1.246.0.zip | Signature | ||
ixt68x64.sys | 4.1.228.0 | intc_ixt68x64_4.1.228.0.zip | Signature | ||
sxa68x64.sys | 4.1.243.0 | intc_sxa68x64_4.1.243.0.zip | Signature | ||
sxb68x64.sys | 4.1.239.0 | intc_sxb68x64_4.1.239.0.zip | Signature | ||
v1q68x64.sys | 1.4.7.3 | intc_v1q68x64_1.4.7.3.zip | Signature | ||
vxn68x64.sys | 2.1.241.0 | intc_vxn68x64_2.1.241.0.zip | Signature | ||
vxs68x64.sys | 2.1.230.0 | intc_vxs68x64_2.1.230.0.zip | Signature |
ThinkServer Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe Gen 4 VPI Adapter |
Part Number: 4XC7A08313 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Mellanox Firmware for C4C (For Windows) | c4c-5.4-1.0.3.0-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
mlx5.sys | 2.50.23317.0 | mlnx_mlx5_2.50.23317.0.zip | Signature | ||
MlxRshimBus.sys | 2.50.23317.0 | mlnx_MlxRshimBus_2.50.23317.0.zip | Signature | ||
MlxRshimCom.sys | 2.50.23317.0 | mlnx_MlxRshimCom_2.50.23317.0.zip | Signature | ||
MlxRshimEth.sys | 2.50.23317.0 | mlnx_MlxRshimEth_2.50.23317.0.zip | Signature |
ThinkServer Intel X710-DA2 OCP 3.0 10Gb 2-Port SFP+ Ethernet Adapter |
Part Number: 4XC7A62643 | ||||
---|---|---|---|---|---|
Core System Device Install Drivers on all Servers | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
Intel v26.6 Network FW Update Windows Release for SR590V2 platform (For Windows) | net.sr590v2-1.3082.0-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
e1d68x64.sys | 12.19.1.37 | intc_e1d68x64_12.19.1.37.zip | Signature | ||
e1r68x64.sys | 12.18.13.0 | intc_e1r68x64_12.18.13.0.zip | Signature | ||
e1s68x64.sys | 12.15.184.4 | intc_e1s68x64_12.15.184.4.zip | Signature | ||
i40ea68.sys | 1.16.62.0 | intc_i40ea68_1.16.62.0.zip | Signature | ||
i40eb68.sys | 1.16.62.0 | intc_i40eb68_1.16.62.0.zip | Signature | ||
ixn68x64.sys | 4.1.239.0 | intc_ixn68x64_4.1.239.0.zip | Signature | ||
ixs68x64.sys | 4.1.246.0 | intc_ixs68x64_4.1.246.0.zip | Signature | ||
ixt68x64.sys | 4.1.228.0 | intc_ixt68x64_4.1.228.0.zip | Signature | ||
sxa68x64.sys | 4.1.243.0 | intc_sxa68x64_4.1.243.0.zip | Signature | ||
sxb68x64.sys | 4.1.239.0 | intc_sxb68x64_4.1.239.0.zip | Signature | ||
v1q68x64.sys | 1.4.7.3 | intc_v1q68x64_1.4.7.3.zip | Signature | ||
vxn68x64.sys | 2.1.241.0 | intc_vxn68x64_2.1.241.0.zip | Signature | ||
vxs68x64.sys | 2.1.230.0 | intc_vxs68x64_2.1.230.0.zip | Signature |
ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA |
Part Number: 4Y37A78602 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0208 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem 440-x SAS/SATA 12Gb HBA update BIOS and Firmware (For Windows) | mpt3.5.440-18.125.04.00-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
itsas35.sys | 2.61.29.02 | lnvgy_itsas35_2.61.29.02.zip | Signature | ||
lsinodrv.sys | 2.61.29.02 | lnvgy_lsinodrv_2.61.29.02.zip | Signature | ||
Utility | Utility Description - Download Page Link (lenovo.com) | Version | |||
StorCLI command line tool (For Windows) | mpt3.storcli-007.1907.0000.0000-0 |
ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter |
Part Number: 4Y37A78835 | ||||
---|---|---|---|---|---|
PCIe Sub Vendor ID: 0x1D49 PCIe Sub Device ID: 0x0506 | |||||
Firmware | Required Firmware Description - Download Page Link (lenovo.com) | Version | |||
ThinkSystem RAID 540-x Adapters update BIOS and Firmware (For Windows) | mr3.5.540-52.19.0-4165-0 | ||||
Drivers | Driver Name (Included in Bundle) | Version | Driver Package - Provided in Bundle | Signature | |
megasas35.sys | 7.719.06.00 | lnvgy_megasas35_7.719.06.00.zip | Signature | ||
nodev.sys | 7.719.06.00 | lnvgy_nodev_7.719.06.00.zip | Signature | ||
Utility | Utility Description - Download Page Link (lenovo.com) | Version | |||
StorCLI command line tool (For Windows) | mr3.storcli-007.1907.0000.0000-0 |
Lenovo Data Center Group Windows Server OS Support Home Page |